Uploaded image for project: 'Quality Control ICS'
  1. Quality Control ICS
  2. QCICS-13

Define the Master that any differences are measured against

    XMLWordPrintable

    Details

    • Type: Story
    • Status: Implemented (View Workflow)
    • Priority: Normal
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: 2.1
    • Component/s: CusQC
    • Labels:
      None

      Description

      The ideal master that defines a delta (ABCDE) of 0 can be different, depending on the workflow

      • absolute colorimetric values
      • a "good sheet" that has been accepted by the customer
      • more?

      This needs to be specified in measurements and in setup

      • Measurements - what is the delta defined against (or do we always provide absolute measurements)
      • setup what ist the tolerance defined for?

        Draft

        Table 6.146: QualityControlParams Resource

        QualityBase ? w? r See XJDF
        Absolute w? r The measurement values defined in subelements of this QualityControlParams are absolute target values. Any calculations of QualityControlResults/@Severity SHALL be based on absolute values.
        Master w? r The measurement values defined in subelements of this QualityControlParams are absolute target values for a master measurement e.g. a signed press sheet. Any calculations of QualityControlResults/@Severity SHALL be based on values provided in QualityControlResult[@MeasurementUsage="Master"].

        Table 6.146: QualityControlResult Resource

        MeasurementUsage r w @MeasurementUsage SHALL specify the usage of this QualityControlResult.
        Standard r w<-- The measurement values defined in subelements of this QualityControlResult are measurement values that SHALL be evaluated regularly.
        Master r w<-- The measurement values defined in subelements of this QualityControlResult specify a master measurement e.g. a signed press sheet. All subsequent measurements with @MeasurementUsage="Standard"shall be compared to the master measurement. A value of Master SHALL be specified exactly one time if the value of QualityControlParams/@QualityBase="Master" in the request for this quality control measurement and SHALL NOT be specified otherwise.
         

          Attachments

            Issue Links

              Activity

                People

                • Assignee:
                  Unassigned
                  Reporter:
                  prosi Rainer Prosi
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  3 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: