Uploaded image for project: 'XJDF / JDF'
  1. XJDF / JDF
  2. JDF-602

CLONE - Define the Master that any differences are measured against

    XMLWordPrintable

    Details

      Description

      The ideal master that defines a delta (ABCDE) of 0 can be different, depending on the workflow

      • absolute colorimetric values
      • a "good sheet" that has been accepted by the customer
      • more?

      This needs to be specified in measurements and in setup

      • Measurements - what is the delta defined against (or do we always provide absolute measurements)
      • setup what ist the tolerance defined for?

        Draft

        Table 6.146: QualityControlParams Resource

        QualityBase ? NMTOKEN @QualityBase SHALL specify the basis of the ideal master measurement.
        Values include:
        Absolute: The measurement values defined in subelements of this QualityControlParams are absolute target values.
        Master: The measurement values defined in subelements of this QualityControlParams are absolute target values for a master measurement e.g. a signed press sheet. All subsequent measurements shall be compared to the master measurement.

        Table 6.146: QualityControlResult Resource

        MeasurementUsage ? enumeration @MeasurementUsage SHALL specify the usage of this QualityControlResult .
        Allowed Values are:
        Standard: The measurement values defined in subelements of this QualityControlResult are measurement values that SHALL be evaluated regularly.
        Master: The measurement values defined in subelements of this QualityControlResult specify a master measurement e.g. a signed press sheet. All subsequent measurements with @MeasurementUsage="Standard"shall be compared to the master measurement.

        ================ Draft 2 ================

        QualityBase ? NMTOKENenumeration @QualityBase SHALL specify the basis of the ideal target master measurement.
        Values include:Allowed values are:
        Absolute - The measurement values defined in subelements of this
        QualityControlParams are SHALL be absolute target values.
        Master - The measurement values defined in subelements of this
        QualityControlParams are SHALL be absolute target values for a master measurement
        e.g. a signed press sheet. All subsequent measurements shall be
        compared to the master measurement. The master measurement SHOULD be identified by providing a QualityControlResult with @MeasurementUsage="Master"
         

          Attachments

            Issue Links

              Activity

                People

                • Assignee:
                  Unassigned
                  Reporter:
                  prosi Rainer Prosi
                • Votes:
                  0 Vote for this issue
                  Watchers:
                  2 Start watching this issue

                  Dates

                  • Created:
                    Updated:
                    Resolved: