Uploaded image for project: 'XJDF / JDF'
  1. XJDF / JDF
  2. JDF-602

CLONE - Define the Master that any differences are measured against

    XMLWordPrintable

    Details

    • Draft:
      Hide

      Table 6.146: QualityControlParams Resource

      QualityBase ? NMTOKEN @QualityBase SHALL specify the basis of the ideal master measurement.
      Values include:
      Absolute: The measurement values defined in subelements of this QualityControlParams are absolute target values.
      Master: The measurement values defined in subelements of this QualityControlParams are absolute target values for a master measurement e.g. a signed press sheet. All subsequent measurements shall be compared to the master measurement.

      Table 6.146: QualityControlResult Resource

      MeasurementUsage ? enumeration @MeasurementUsage SHALL specify the usage of this QualityControlResult .
      Allowed Values are:
      Standard: The measurement values defined in subelements of this QualityControlResult are measurement values that SHALL be evaluated regularly.
      Master: The measurement values defined in subelements of this QualityControlResult specify a master measurement e.g. a signed press sheet. All subsequent measurements with @MeasurementUsage="Standard"shall be compared to the master measurement.

      ================ Draft 2 ================

      QualityBase ? NMTOKENenumeration @QualityBase SHALL specify the basis of the ideal target master measurement.
      Values include:Allowed values are:
      Absolute - The measurement values defined in subelements of this
      QualityControlParams are SHALL be absolute target values.
      Master - The measurement values defined in subelements of this
      QualityControlParams are SHALL be absolute target values for a master measurement
      e.g. a signed press sheet. All subsequent measurements shall be
      compared to the master measurement. The master measurement SHOULD be identified by providing a QualityControlResult with @MeasurementUsage="Master"
      Show
      Table 6.146: QualityControlParams Resource QualityBase ? NMTOKEN @QualityBase SHALL specify the basis of the ideal master measurement. Values include: Absolute: The measurement values defined in subelements of this QualityControlParams are absolute target values. Master: The measurement values defined in subelements of this QualityControlParams are absolute target values for a master measurement e.g. a signed press sheet. All subsequent measurements shall be compared to the master measurement. Table 6.146: QualityControlResult Resource MeasurementUsage ? enumeration @MeasurementUsage SHALL specify the usage of this QualityControlResult . Allowed Values are: Standard: The measurement values defined in subelements of this QualityControlResult are measurement values that SHALL be evaluated regularly. Master: The measurement values defined in subelements of this QualityControlResult specify a master measurement e.g. a signed press sheet. All subsequent measurements with @MeasurementUsage="Standard"shall be compared to the master measurement. ================ Draft 2 ================ QualityBase ? NMTOKEN enumeration @QualityBase SHALL specify the basis of the ideal target master measurement. Values include: Allowed values are: Absolute - The measurement values defined in subelements of this QualityControlParams are SHALL be absolute target values. Master - The measurement values defined in subelements of this QualityControlParams are SHALL be absolute target values for a master measurement e.g. a signed press sheet. All subsequent measurements shall be compared to the master measurement. The master measurement SHOULD be identified by providing a QualityControlResult with @MeasurementUsage="Master"

      Description

      The ideal master that defines a delta (ABCDE) of 0 can be different, depending on the workflow

      • absolute colorimetric values
      • a "good sheet" that has been accepted by the customer
      • more?

      This needs to be specified in measurements and in setup

      • Measurements - what is the delta defined against (or do we always provide absolute measurements)
      • setup what ist the tolerance defined for?

        Attachments

          Issue Links

            Activity

              People

              • Assignee:
                Unassigned
                Reporter:
                prosi Rainer Prosi
              • Votes:
                0 Vote for this issue
                Watchers:
                2 Start watching this issue

                Dates

                • Created:
                  Updated:
                  Resolved: